Swfault, Swsensorscn, Swfcportscn – Dell POWEREDGE M1000E User Manual
Page 157
 
Fabric OS MIB Reference
137
53-1002750-01
sw traps
6
TABLE 44
Trap name and OID
Variables
Description
swFault
1.3.6.1.4.1.1588.2.1.1.1
.0.1
This trap is no longer generated.
A swFault is generated whenever the diagnostics 
detect a fault with the switch.
#TYPE
Switch is faulty.
#SUMMARY
Faulty reason: %d and SSN is #%s
#ARGUMENTS 0, 1
#SEVERITY
Critical
#TIMEINDEX 1
#STATE
Nonoperational
swSensorScn
1.3.6.1.4.1.1588.2.1.1.1
.0.2
swSensorStatus
swSensorIndex
swSensorType
swSensorValue
swSensorInfo
swSsn
This object is obsoleted by
A swSensorScn (2) is generated whenever an 
environment sensor changes its operational state: 
for instance, if a fan stop working. The VarBind in the 
Trap Data Unit contain the corresponding instance of 
the sensor status, sensor index, sensor type, sensor 
value (reading), and sensor information. Note that 
the sensor information contains the type of sensor 
and its number, in textual format.
#TYPE
A sensor (temperature, fan, or other)
changed its operational state.
#SUMMARY
%s: is currently in state %d and SSN is 
#%s
#ARGUMENTS 4, 0, 5
#SEVERITY
Informational
#TIMEINDEX 1
#STATE
Operational
swFCPortScn
1.3.6.1.4.1.1588.2.1.1.1
.0.3
swFCPortOpStatus
swFCPortIndex
swFCPortName
swFCPortWwn
swFCPortPrevType
swFCPortBrcdType
swSsn
swFCPortFlag
swVfId
A swFCPortScn (3) is generated whenever an FC port 
changes its operational state or port type. The events 
that trigger this trap are as follows:
•
Port changes its state to online or offline.
•
Port type changes to E_port, F_port, or FL_port.
The VarBind in the Trap Data Unit contains the 
corresponding instance of the FC port's operational 
status, index, swFCPortName, and swSsn. 
swFCPortName and swSsn are optional.
#TYPE
A Fibre Channel Port changed its
operational state.
#SUMMARY
Port Index %d changed state to %d.
Port Name: %s and SSN is #%s
#ARGUMENTS 1, 0, 2, 3
#SEVERITY
Informational
#TIMEINDEX 1
#STATE
Operational