224

Fabric OS MIB Reference

53-1002750-01

Connectivity unit group

9

connUnitLinkIndex
1.3.6.1.3.94.1.12.1.2

Read only

This value is used to create a unique value for each entry in the link
table with the same connUnitLinkUnitId. The value can only be reused if
it is not currently in use and the value is the next candidate to be used.
This value is allowed to wrap at the highest value represented by the
number of bits. This value is reset to 0 when the system is reset and the
first value to be used is 1.
Indexes 1 through maximum number of ports is reserved for ISL.
Indexes maximum number of ports + 1 and above are reserved for end
devices and are calculated based on portID of the end devices.

connUnitLinkNodeIdX
1.3.6.1.3.94.1.12.1.3

Read only

The node WWN of the unit at one end of the link. If the node WWN is
unknown and the node is a connUnit in the responding agent, then the
value of this object must be equal to its connUnitID.
WWN of the local switch.

connUnitLinkPortNumbe
rX
1.3.6.1.3.94.1.12.1.4

Read only

The port number on the unit specified by connUnitLinkNodeIdX, if
known; otherwise, -1. If the value is nonnegative, then it is equal to
connUnitPortPhysicalNumber.
ISL- Physical port number of the E_Port.
Device- Physical port # to which the device is connected.

connUnitLinkPortWwnX
1.3.6.1.3.94.1.12.1.5

Read only

The port WWN of the unit specified by connUnitLinkNodeIdX, if known;
otherwise, 16 octets of binary 0.
This is the WWN of the port to which the device is connected.

connUnitLinkNodeIdY
1.3.6.1.3.94.1.12.1.6

Read only

The node WWN of the unit at the other end of the link. If the node WWN
is unknown and the node is a connUnit in the responding SNMP agency,
then the value of this object must be equal to its connUnitID.
ISL- WWN of the remote switch.
Device- Node name of the device.

connUnitLinkPortNumbe
rY
1.3.6.1.3.94.1.12.1.7

Read only

The port number on the unit specified by connUnitLinkNodeIdY, if
known; otherwise, -1. If the value is nonnegative then it is equal to
connUnitPortPhysicalNumber.
ISL- Physical port number of the remote port.
Device: -1.

connUnitLinkPortWwnY
1.3.6.1.3.94.1.12.1.8

Read only

The port WWN on the unit specified by connUnitLinkNodeIdY, if known;
otherwise, 16 octets of binary 0.
ISL- WWN of the remote port.
Device- Port name.

connUnitLinkAgentAddre
ssY
1.3.6.1.3.94.1.12.1.9

Read only

The address of an FCMGMT MIB agent for the node identified by
connUnitLinkNodeIdY, if known; otherwise, 16 octets of binary 0.
ISL- IP address (IPv4).
Device- 0 (Null).

connUnitLinkAgentAddre
ssTypeY
1.3.6.1.3.94.1.12.1.10

Read only

If connUnitLinkAgentAddressY is nonzero, it is a protocol address.
connUnitLinkAgentAddressTypeY is the “address family number”
assigned by IANA to identify the address format (for example, 1 is Ipv4, 2
is Ipv6).
ISL- Type 1.
Device- 0 (Null).

connUnitLinkAgentPortY
1.3.6.1.3.94.1.12.1.11

Read only

The IP port number for the agent. This is provided in case the agent is at
a non-standard SNMP port.
ISL- IP port.
Device- 0 (Null).

TABLE 75

Object and OID

Access

Description

Advertising