8 quick start interface connection – CANOGA PERKINS 9140 Four-Port SNMP Managed Fast Ethernet Switch User Manual

Page 19

Advertising
background image

EdgeAccess SNMP Managed Fast Ethernet Switch

Model 9135/9140

1-9

1.8 Quick Start Interface Connection

Caution: To protect the Ethernet port from an intrabuilding lightening surge, use a properly grounded

shielded cable.


Step 1 In this installation step, connect the Category 5 UTP jumper cable from the customer's equipment

into the RJ-45 receptacle on the 10/100BASE-TX module. Reference Figure 1-7.


Note: Step 1 must be repeated on both local and remote switches.


Figure 1-7. 9135 or 9140 UTP and SMF Interface Connectors and LEDs.



Step 2 The following LEDs verify the correct operation of the local and remote switch UTP interface,

the CAT 5 UTP jumper cable, and the 9135 or 9140 10/100BASE-TX UTP interface.

Lnk

ON

Indicates that good idle signals are received from the other UTP
interface transmitter via the UTP cable.

Aut

ON

This

indicates

auto

negotiation

is

active.


100

ON

This indicates 100Mbps operation.

OFF

This indicates 10Mbps operation.

Fdx mode

ON

This indicates that the unit is in full-duplex mode.

OFF

This indicates that the unit is in half-duplex mode.

Step 3 Connect the fiber optic jumper cable from the fiber patch panel or other 9135/9140 switch and

insert into the 100BASE-FX connector on the 9135/9140 optical interface.

Note: This step must be repeated on both local and remote 9135 or 9140 100BASE-FX interfaces.