Comtech EF Data CDM-840 User Manual

Page 115

Advertising
background image

CDM-840 Remote Router

Revision 2

Ethernet-based Remote Product Management

MN-CDM840

6–47

BUC Low or High Current Limit (0 to 4000) – Enter the BUC current alarm for either limit in

100mA increments.

Set the desired BUC configurations. Click [Submit BUC Control] to save.

BUC Status

BUC Power Supply, BUC Voltage (V), and BUC Current (mA) – When the presence of BUC Power

Supply is detected, it is acknowledged here and its voltage and current information is

continuously monitored and is provided on a read-only basis.

Click [Refresh] to update this section with its latest available statistics.

6.4.4.5.2.7

Configuration | WAN | LNB (Low Noise Block Downconverter)

This page is operational only when an optional LOW-NOISE BLOCK

DOWNCONVERTER is installed.

Use this page to configure Low-Noise Block Downconverter parameters, and to display the LNB

status for L-Band operation.

Figure 6-22. Configuration | WAN | LNB Page

LNB Control

The acceptable/valid operating range for each item in this section is provided in parentheses.

LNB DC Power – Use the drop-down list to select the power as Off, 13V, 18V, or 24V.