9 unit parameters commands and queries, T. 6.3.9 – Comtech EF Data CDM-840 User Manual

Page 165

Advertising
background image

CDM-840 Remote Router

Revision 2

Serial-based Remote Product Management

MN-CDM840

7–19

7.3.9

Unit Parameters Commands and Queries

Parameter

Type

Command

(Instruction

Code

& Qualifier)

Number of

Arguments for

Command or

Response to Query

Description of Arguments

(Note that all arguments are ASCII numeric codes from 48 and 57)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code &

Qualifier)

Response to Query

(Target to Controller)

Equipment ID N/A

37 bytes

Query only.

Returns the equipment ID and installed options, where:

AAAA= The modem model number, i.e, 0840

ssss (4 spares)= Installed hardware = 0000

Software FAST options

B= Tx Data/Symbol Rate option:

0= Standard: CCM 16kbps to 256kbps

1= CCM 16kbps to 512bps

2= CCM 16kbps to 1024kbps

3= CCM 16kbps to 2048kbps

4= CCM 16kbps to 5Mbps

5= CCM 16kbps to 10Mbps

6= CCM 16kbps to 15Mbps

7= ACM 37ksps to 100ksps (future)

8= ACM 37ksps to 200ksps (future)

9= ACM 37ksps to 400ksps (future)

A= ACM 37ksps to 800ksps (future)

B= ACM 37ksps to 1200ksps (future)

C= ACM 37ksps to 2400ksps (future)

D= CCM 37ksps to 4100 ksps (future)

C= Rx Data/Symbol Rate option:

0= Standard: CCM 1Mbps to 15Mbps

1= CCM 1Mbps to 45Mbps

2= CCM 1Mbps to 100Mbps

3= CCM 1Mbps to 140Mbps

4= CCM 1Mbps to 167Mbps

5= ACM 1Msps to 5Msps future

6= ACM 1Msps to 15Msps future

7= ACM 1Msps to 34Msps future

8= ACM 1Msps to 47Msps future

9= ACM 1Msps to 62Msps future

N/A

EID?

EID=AAAAssssBCDEFGHIJ

Ksssssssssssssssssss

(see Description of

Arguments)

Advertising