CDM-840 Remote Router

Revision 2

Ethernet-based Remote Product Management

MN-CDM840

6–77

To load (recall) a configuration set:

o First, use the bottom (Load) Select Location dropdown to select 1 through 10.

o Then, click [Load Configuration] to recall the selected configuration settings.

BERT Config

(Where BERT is the acronym for Bit Error Rate Test) Use the drop-down lists to:

• Configure the Tx or Rx BERT State as On or Off.

• Configure the Tx or Rx BERT Pattern as 2^23-1 (2

23

-1) or 2047.

• Set Error Insertion as either Off or 10E-3.

Select the desired BERT settings. Click [Submit] to save the settings and execute the test.

BERT Monitor

This section displays the ongoing BERT. Click [Restart] to restart the BERT Monitor. Otherwise,

click [Update] to refresh a test already in progress.

Once the Tx BERT is executed, the entire outbound carrier transmits a BERT pattern.

All IP communications are halted during this test.

Note also that the Rx BERT State for the CDM-840 must be enabled for a CDM-800

Gateway Router to properly receive and monitor the BERT pattern.

Redundancy

Current Redundancy State (read-only) – Status is listed as On Line or Off Line.

Offline Unit Status (read-only) – This indicates the status of the offline unit.

If the unit is not connected to a redundancy switch, the status is listed as No_1F1.

Otherwise, its status is listed as On Line or Off Line.

If the unit is part of a 1:1 or 1:N redundant pair of CDM-840s, and this unit is currently On Line,

click [Force Redundancy Switch] to cause the unit to switch to standby.

Console Configuration

Use the drop-down list to select the desired communications protocol for the rear panel

CONSOLE’ port. Click [Submit] to save. The available selections are:

o RS232-8N1-38400

o RS485-8N1-9600

o RS485-8N1-19200

o RS485-8N1-38400

o RS485-8N1-57600

o RS485-8N1-115200