6 optional message arguments, 7 end of packet – Comtech EF Data CDM-840 User Manual

Page 153

Advertising
background image

CDM-840 Remote Router

Revision 2

Serial-based Remote Product Management

MN-CDM840

7–7

Character

Definition

*

(ASCII code 42)

If the Controller sends the command to set a parameter to a particular value, and the value sent is valid BUT the router will not permit

that particular parameter to be changed at present, the Target acknowledges the message and responds with, for example, MLC* (with

message arguments).

#

(ASCII code 35)

If the Controller sends a correctly formatted command, BUT the unit is not in Remote Mode, it does not allow reconfiguration and

responds, for example, with MLC#.

7.2.2.6 Optional Message Arguments

Arguments are not required for all messages. Arguments are ASCII codes for the characters ‘0’ to ‘9’ (ASCII codes 48 to 57), period ‘.

(ASCII code 46), and comma ‘,’ (ASCII code 44).

7.2.2.7 End of Packet

Controller-to-Target: This is the ‘Carriage Return’ ([CR]) character (ASCII code 13).

Target-to-Controller: This is the two-character sequence ‘Carriage Return’, ‘Line Feed’ ([cr][lf]) (ASCII codes 13 and 10). Both

indicate the valid termination of a packet.

Advertising