3.3.2.2 AC Operation – Replacing Fuses

The CDM-840 uses two 5mm x 20mm Slow-blow fuses – one each for line and neutral

connections. The fuses are contained within a fuse holder that is press-fit into the body of the

power supply module located on the rear panel (Figure 3-7).

Figure 3-7. Replacing CDM-840 AC Fuses

To replace the fuses:

DISCONNECT THE POWER SUPPLY BEFORE PROCEEDING!

First, unseat the fuse holder from the IEC power module.

o Use the slot to pry the holder outward from the IEC power module.

o Pull the holder straight out, and then swing the holder away from the module.

Then, remove and replace the fuses as needed.

o Use T2.5A (2.5 Amp) fuses for standard operation.

o Use T4A (4 Amp) fuses when a Block Upconverter (BUC) is installed.

FOR CONTINUED OPERATOR SAFETY, ALWAYS REPLACE THE FUSES WITH THE

CORRECT TYPE AND RATING.

Finally, re-seat the fuse holder in the IEC power module.