2 dc operation – replacing fuses – Comtech EF Data CDM-840 User Manual

Page 54

Advertising
background image

CDM-840 Remote Router

Revision 2

Rear Panel Connections

MN-CDM840

3–14

3.3.3.2 DC Operation – Replacing Fuses

The fuses are contained within individual screw-in receptacles located below the power supply

terminal block (Figure 3-10).

Figure 3-10. Replacing CDM-840 DC Fuses

To replace the fuses:

DISCONNECT THE POWER SUPPLY BEFORE PROCEEDING!

First, unscrew either fuse holder from its receptacle. Then, remove and replace the

fuse(s):

o Use T3A (3 Amp) fuses for standard operation

o Use T5A (5 Amp) fuses when a Block Upconverter (BUC) is installed.

FOR CONTINUED OPERATOR SAFETY, ALWAYS REPLACE THE FUSES WITH

THE CORRECT TYPE AND RATING.

Screw either fuse holder back into its receptacle.

Advertising