Tx LO Frequency – Assign a value, in MHz, to the Tx LO (Low Oscillator) Frequency.

Base Power (–40.0 to 0.0) – Enter the power level, in dBm, for transmission of the Aloha

ECM signal. This level was determined for this unit when its terminal was commissioned,

and must be calibrated with the satellite provider.

Click [Submit] to save.

ECM Remote Status (read-only)

Cycle Length – The Cycle Length is the total length of time, in milliseconds, between the

start of a transmission and the completion of the transmission cycle (TAP) transmitted by

the CDD-880 to the CDM-840 or CDM-840 Remote Routers in the ECM group. It is the

product of the number of slots and the slot length (consisting of the preamble, data slot

size, and guard band).

Aloha State – The Aloha State indicates the current state of this unit during the ECM cycle:

Unit State

Description

Idle

Unit is not transmitting; either inactive or waiting for switching assignment.

Active

Unit is actively transmitting (probing) to the Hub for either registration or request for switching

to dSCPC.

Switched

Remote has successfully switched from ECM to dSCPC.

Current Tap – Indicates current value of sequential progression of TAP message

transmission. Ranges from 0 to 255, then repeats.

Current Slot – The time slot number that has been assigned to this unit in the transmission

cycle for switching from ECM to dSCPC.

Home State Revert Timer – The time, in seconds, that must pass without receiving

communications from the HCC (Hub Channel Controller – i.e., Demod #1 on the CDD-880,

the designated ECM controller) TAP message before this unit is reverted from dSCPC mode

back to ECM to re-establish communications settings for receiving the TAP. This parameter

is set in the VMS.

Probing Duration – Amount of time, in seconds, that this unit has been transmitting to the

HCC to request registration and switchout.

Seconds Until Next Probe – The time period, in seconds, before this unit will again transmit

to the HCC.