Comtech EF Data CDM-840 User Manual

Page 168

Advertising
background image

CDM-840 Remote Router

Revision 2

Serial-based Remote Product Management

MN-CDM840

7–22

Parameter

Type

Command

(Instruction

Code

& Qualifier)

Number of

Arguments for

Command or

Response to Query

Description of Arguments

(Note that all arguments are ASCII numeric codes from 48 and 57)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code &

Qualifier)

Response to Query

(Target to Controller)

Faults and

Status

N/A

16 bytes

Query only.

Returns the current highest-priority fault and status codes for the Unit (hardware),

TX Traffic, RX Traffic, and ODUs in the form abcdefxxxxxxxxxx, where:

a = Unit status:

0=No faults

1=Power supply fault, +5 volts

2=Power supply fault , +12 volts

3=Tx synthesizer unlocked

4=Tx/Rx FPGA PLL unlocked

5=Tx/Rx FPGA load fail

6=Compression FPGA load fail

b = Tx Traffic status:

0=Tx traffic OK

c = Rx Traffic status:

0=Rx Traffic OK

1=Demodulator unlocked

2=Es/No Alarm

d = BUC status/faults:

0=BUC OK

1=BUC Current

2=BUC Voltage

e = LNB status/faults:

0 = OK, masked or not present

1 = LNB current

2 = LNB voltage

f = Traffic/GE Interface Fault (reports as Unit Fault)

0 = OK

1 = No Link

sssssssssssssssssss (10 spares)

Example: <0/FLT?’cr’

N/A

FLT?

FLT= abcdefxxxxxxxxxx

(see Description of

Arguments)

Software

Boot From

Slot

SBS=

1 byte

Command or Query.

Selects which bulk firmware slot to boot from in the form x, where:

0=Latest Firmware (most recent date)

1=Firmware is Slot #1

2=Firmware is Slot #2

Example: <1/SBS=1’cr’

SBS=

SBS?

SBS*

SBS#

SBS?

SBS=x

(see Description of

Arguments)