1 dc operation – applying power – Comtech EF Data CDM-840 User Manual

Page 53

Advertising
background image

CDM-840 Remote Router

Revision 2

Rear Panel Connections

MN-CDM840

3–13

3.3.3

48V Direct Current (DC) Power Interface (Optional)

Figure 3-8. CDM-840 DC Power Interface

3.3.3.1 DC Operation – Applying Power

Figure 3-9. Applying DC Power to the CDM-840

To apply DC power to the CDM-840:

• First, connect the user-supplied (+) and (–) DC power leads to their respective terminals.

Number 18 AWG minimum wires are recommended.

• Then, connect the user-supplied DC power leads to the power source.

• Finally, switch the unit ON.

Feature

Description

1

On / Off Switch

2

Screw-in Fuse Holders / Receptacles

3

Power Terminal Block

DC Power Specifications

Input Power

25W (typical)

245W (maximum with BUC)

Input Voltage

48V DC, nominal

(36V to 60V)

Connector Type

Terminal Block

Fuse Protection

(2X) 5mm x 20mm Slow-blow type fuses:

T3A (3.0A) Main

T5A (5.0A) (BUC)

Advertising