Cable – gas console to ignition console b-11 – Hypertherm HD4070 Rev.1 User Manual

Page 111

Advertising
background image

2-TORCH INSTALLATION

HyPerformance HD4070

Instruction Manual

3B-11

Cable – gas console to ignition console

16

Part no.

Length

123446

3 m (10 ft)

123447

6 m (20 ft)

123448

7.5 m (25 ft)

123449

9 m (30 ft)

123450

12 m (40 ft)

Part no.

Length

123512

15 m (50 ft)

123559

18 m (60 ft)

123513

23 m (75 ft)

123514

30.5 m (100 ft)

CABLE RUN LIST

Signal name

2X1

Color

3X3/4

Function

Input/Output

Not used

13

Grey

13

Not used

25

Brown

25

Not used

12

Red

12

Not used

24

Yellow

24

Not used

11

Red

11

Not used

23

Blue

23

Not used

10

Red

10

Not used

22

Green

22

Not used

9

Red

9

Not used

21

White

21

Not used

8

Red

8

Not used

20

Orange

20

Not used

7

Black

7

Vent-120 VAC return

19

Brown

19

Energizes the vent solenoid

Output

Vent-120 VAC

6

Black

6

Output

Plasma cutflow-120 VAC return

18

Yellow

18

Energizes the plasma cutflow solenoid

Output

Plasma cutflow-120 VAC

5

Black

5

Output

Plasma preflow-120 VAC return

17

Blue

17

Energizes the plasma preflow solenoid

Output

Plasma preflow-120 VAC

4

Black

4

Output

Shield cutflow-120 VAC return

16

Green

16

Energizes the shield cutflow solenoid

Output

Shield cutflow-120 VAC

3

Black

3

Output

Shield preflow-120 VAC return

15

White

15

Energizes the shield preflow solenoid

Output

Shield preflow-120 VAC

2

Black

2

Output

Ignitor-120 VAC return

14

Red

14

Energizes the ignitor

Output

Ignitor-120 VAC

1

Black

1

Output

2X1

3X3/4

Advertising