Mild steel – Hypertherm HD4070 Rev.1 User Manual

Page 145

Advertising
background image

OPERATION

4-20

HyPerformance HD4070

Instruction Manual

Mild steel

O

2

Plasma / O

2

-N

2

Shield

80A Cutting

Pierce height = torch-to-work distance X pierce height factor

220173

220189

220176

220188

220179

220187

Metric

English

O2

N2

O2

N2

O2

N2

O2

N2

in

ipm

%

seconds

14/.075

112

400

12/.105

115

290

10/.135

117

180

3/16

119

155

1/4

121

110

0.3

5/16

123

92

0.4

3/8

124

75

0.5

7/16

125

62

0.6

1/2

126

50

0.7

150

200

250

0.1

0.2

0.100

0.080

34

0

10

24

11

48

11

34

15

52

Test Preflow Rate (%)

Test Cutflow Rate (%)

Material

Thickness

gauge/inch

Arc

Voltage

Plasma

Shield

Plasma

Shield

Torch-to-

Work

distance

Cutting

Speed

Pierce

Height

Factor

Pierce

Delay

O2

N2

O2

N2

O2

N2

O2

N2

mm

mm/m

%

seconds

2

112

9650

0.1

3

117

6050

4

119

4225

5

120

3600

6

121

3000

8

123

2000

0.4

10

124

1775

0.5

11

34

12

126

1400

250

0.7

34

0

10

24

15

52

0.2

150

200

11

48

2.5

2.0

0.3

Test Preflow Rate (%)

Test Cutflow Rate (%)

Material

Thickness

millimeters

Arc

Voltage

Plasma

Shield

Plasma

Shield

Torch-to-

Work

distance

Cutting

Speed

Pierce

Height

Factor

Pierce

Delay

Advertising