Hypertherm HD4070 Rev.1 User Manual

Page 263

Advertising
background image

APPENDIX A – SYSTEM GROUNDING

HyPerformance HD4070

Instruction Manual

a-3

Figure a-1

Recommended ground connection configuration

Note:

Configuration may vary for each installation and may require a different ground scheme.

Plasma power supply

(PE)

(PE)

(PE)

(PE)

Power cord
ground

Ferrite choke

Supplementary
grounding rod

Gas console

Other equipment

receiving power from the
plasma power supply

Ignition console

Work table

Advertising