OPERATION

4-12

HyPerformance HD4070

Instruction Manual

TRAVEL SPEED: 84 IPM

INLET GAS: O2 N2

CUT HEIGHT: 0.156 IN

SET ARC VOLTS: 144.0 V

TRAVEL SPEED: 84 IPM

INLET GAS: O2 N2

CUT HEIGHT: 0.156 IN

SET ARC VOLTS: 144.0 V

System operation screens – continued

4

Use the ARC VOLT buttons to adjust the arc volts.

Adjust arc volts

Adjust torch height

The lifter can be manually moved up or down in two ways.
For large adjustments, press the AUTO MAN THC button
and then use the JOG UP and JOG DOWN buttons. The
lifter will continue to move as long as the button is
pressed. For small adjustments, press the AUTO MAN
THC button again and use the STEP UP and STEP
DOWN buttons. Each time you press the UP or DOWN
button the lifter will move .08 mm (.003 inches).

IMPORTANT: When the JOG UP and JOG DOWN or the
STEP UP and STEP DOWN buttons are displayed, the
Arc Volt Torch Height Control function is disabled. To
restore Arc Volt Torch Height Control, press the AUTO
MAN THC button until you return to the original screen.