Instruction Manual

5-13

MAINTENANCE

NEXT

PORT 0

00000000

PORT 2

00000000

PORT 1

00000000

PORT 3

00000000

PORT 8

00000000

PORT 10

00000000

PORT 9

00000000

PORT 11

00000000

PORT 12

00000000

PORT 14

00000000

PORT 13

00000000

PORT 4

00000000

PORT 6

00000000

PORT 5

00000000

PORT 7

00000000

NEXT

PORT 0

00000000

Bit 0-7

17

18

VOLTAGE: 0.0 V

STARTS: 0

ERRORS: 0

HOURS: 0000000.0

STATE:

AMPERAGE: 0.0 A

POWER CHECK: 000.0 V

INLET GAS 1: 0.0 PSI

INLET GAS 2: 0.0 PSI

INLET GAS 3: 0.0 PSI

DISPLAY REV: 0

DATA BASE REV: 0

SOFTWARE REV: 0

Service display screens

Screen 17 is display only. No adjustments can be made.

Amperage – Actual arc current
Power check – Actual measure of 120VAC from control transformer
Inlet gas 1 – Inlet gas pressure (not checked in idle state)
Inlet gas 2 – Inlet gas pressure (not checked in idle state)
Inlet gas 3 – Inlet gas pressure (not checked in idle state)
State – State of power supply

Screen 18 is display only.
Input/Output status: See table in Appendix D for details.

State 0 = Initialization

State 6 = Arc transfer

State 1 = Waiting for user to select process

State 7 = Ramp-up

State 2 = Purge

State 8 = Steady (run) state

State 3 = Idle (waiting for start)

State 9 = Ramp-down

State 4 = Preflow and IHS, if THC is present

State 10 = Final ramp-down

State 5 = Pilot arc

State 11 = Auto OFF
State 14 = Shut-down