Hypertherm HD4070 Rev.1 User Manual

Page 143

Advertising
background image

OPERATION

4-18

HyPerformance HD4070

Instruction Manual

Marking

N

2

or H5 Plasma / N

2

Shield

220173

220202

220304

220201

220180

220308

Gas Rate Gas Rate Gas Rate Gas Rate

Amps

mm

mm/m

Mild Steel

N2

15

N2

40

N2

15

N2

40

7

153.0

6250

Stainless Steel

H5

50

N2

80

H5

40

N2

80

7

84.0

3000

Aluminum

H5

50

N2

80

H5

20

N2

80

10

78.0

4375

2.2

Test Preflow Rate (%)

Plasma

Shield

Material

Torch-to-

Work

Distance

Cutting

Speed

Arc

Voltage

Test Cutflow Rate (%)

Plasma

Shield

Marking

Current

Metric

English

Gas Rate Gas Rate Gas Rate Gas Rate

Amps

in

ipm

Mild Steel

N2

15

N2

40

N2

15

N2

40

7

153.0

250

Stainless Steel

H5

50

N2

80

H5

40

N2

80

7

84.0

120

Aluminum

H5

50

N2

80

H5

20

N2

80

10

78.0

175

0.090

Material

Test Preflow Rate (%)

Test Cutflow Rate (%)

Plasma

Shield

Plasma

Cutting

Speed

Torch-to-

Work

Distance

Arc

Voltage

Marking

Current

Shield