Error code troubleshooting – 4 of 4 -18 – Hypertherm HD4070 Rev.1 User Manual

Page 181

Advertising
background image

5-18

HyPerformance H

D4
0

70
Instruction Manual

MAINTENANCE

Error code troubleshooting – 4 of 4

ID #

Error Code or Message

Description

Corrective action

1 2 3 MV 1 ERROR

Motor valve #1 did not move when commanded.

(1) Check all cables from relay PCB to Motor valves. (2) Check LED for relay
PCB#1, Shown later in this section. (3) Check relay PCB#1 incoming signal.
(4) Check relay PCB#1 output signal. (5) Switch cables to a working MV; If
MV works, replace malfunctioning MV. If MV does not work, replace or repair
cables. (6) Broken wire or cable. P1-4, P12-2, P2-4, PL1 and P3-1 not
seated properly. Pin or socket not seated in plug housing properly. Faulty SSR
on relay board. Loss of signal from control board to relay board.

1 2 4 MV 2 ERROR

Motor valve #2 did not move when commanded.

(1) Check all cables from relay PCB to Motor valves. (2) Check LED for
relay PCB#1, Shown later in this section. (3) Check relay PCB#1 incoming
signal. (4) Check relay PCB#1 output signal. (5) Switch cables to a
working MV; If MV works, replace malfunctioning MV. If MV does not work,
replace or repair cables. (6) Broken wire or cable. P1-5, P12-2, P2-5, PL2
and P3-1 not seated properly. Pin or socket not seated in plug housing
properly. Faulty SSR on relay board. Loss of signal from control board to relay
board.

1 2 5 MV 3 ERROR

Motor valve #3 did not move when commanded.

(1) Check all cables from relay PCB to Motor valves. (2) Check LED for relay
PCB#2, Shown later in this section. (3) Check relay PCB#2 incoming signal.
(4) Check relay PCB#2 output signal. (5) Switch cables to a working MV; If
MV works, replace malfunctioning MV. If MV does not work, replace or repair
cables. (6) Broken wire or cable. P1-6, P12-2, P2-6, PL3 and P2-3 not
seated properly. Pin or socket not seated in plug housing properly. Faulty SSR
on relay board. Loss of signal from control board to relay board.

1 2 6 MV 4 ERROR

Motor valve #4 did not move when commanded.

(1) Check all cables from relay PCB to Motor valves. (2) Check LED for relay
PCB#2, Shown later in this section. (3) Check relay PCB#2 incoming signal.
(4) Check relay PCB#2 output signal. (5) Switch cables to a working MV; If
MV works, replace malfunctioning MV. If MV does not work, replace or repair
cables. (6) Broken wire or cable. P1-7, P12-2, P2-7, PL4 and P2-3 not
seated properly. Pin or socket not seated in plug housing properly. Faulty SSR
on relay board. Loss of signal from control board to relay board.

1 2 7 MV 5 ERROR

Motor valve #5 did not move when commanded.

(1) Check all cables from relay PCB to Motor valves. (2) Check LED for relay
PCB#2, Shown later in this section. (3) Check relay PCB#2 incoming signal.
(4) Check relay PCB#2 output signal. (5) Switch cables to a working MV; If
MV works, replace malfunctioning MV. If MV does not work, replace or repair
cables. (6) Broken wire or cable. P1-8, P10-2, P2-8, PL5 and P2-3 not
seated properly. Pin or socket not seated in plug housing properly. Faulty SSR
on relay board. Loss of signal from control board to relay board.

1 2 8 MV 6 ERROR

Motor valve #6 did not move when commanded.

(1) Check all cables from relay PCB to Motor valves. (2) Check LED for relay
PCB#2, Shown later in this section. (3) Check relay PCB#2 incoming signal.
(4) Check relay PCB#2 output signal. (5) Switch cables to a working MV; If
MV works, replace malfunctioning MV. If MV does not work, replace or repair
cables. (6) Broken wire or cable. P1-9, P10-2, P2-9, PL6 and P2-3 not
seated properly. Pin or socket not seated in plug housing properly. Faulty SSR
on relay board. Loss of signal from control board to relay board.

1 2 9 MV 7 ERROR

Motor valve #7 did not move when commanded.

(1) Check all cables from relay PCB to Motor valves. (2) Check LED for relay
PCB#2, Shown later in this section. (3) Check relay PCB#2 incoming signal.
(4) Check relay PCB#2 output signal. (5) Switch cables to a working MV; If
MV works, replace malfunctioning MV. If MV does not work, replace or repair
cables. (6) Broken wire or cable. P1-10, P10-2, P2-10, PL7 and P2-3 not
seated properly. Pin or socket not seated in plug housing properly. Faulty SSR
on relay board. Loss of signal from control board to relay board.

1 3 0 MV 8 ERROR

Motor valve #8 did not move when commanded.

(1) Check all cables from relay PCB to Motor valves. (2) Check LED for relay
PCB#2, Shown later in this section. (3) Check relay PCB#2 incoming signal.

1 3 1 THC CONTROL FAI

L

I

ndicates a failure on the THC control board.

Replace board.

1 3 2 THC CONTROL FAIL

Indicates a failure on the THC control board.

Replace board.

1 5 0 INTERLOCK (E-STOP)

External emergency stop activated on cutting apparatus.

Reset e-stop at cutting machine.

1 5 1 SOFTWARE FAIL

This is a catch all message indicating that the software has unexpectedly failed
to perform a routine operation.

Cycle power and try and continue operation.

Advertising