Aluminum – Hypertherm HD4070 Rev.1 User Manual

Page 153

Advertising
background image

OPERATION

4-28

HyPerformance HD4070

Instruction Manual

Aluminum

H35-N

2

Plasma / N

2

Shield

130A Cutting

Pierce height = torch-to-work distance X pierce height factor

220173

220198

220304

220197

220179

220307

Metric

English

H35

N2

H35

N2

H35

N2

H35

N2

in

ipm

%

seconds

1/4

156

85

5/16

158

75

3/8

159

65

7/16

159

0.130

60

0.4

1/2

160

55

0.5

9/16

161

52

0.7

5/8

162

45

0.8

3/4

164

35

1.3

0.120

0

31

25

43

0

80

0.3

0

65

0.140

Pierce

Delay

Test Preflow Rate (%)

Test Cutflow Rate (%)

Material

Thickness

inch

Arc

Voltage

Plasma

Shield

Plasma

Shield

Torch-to-

Work

distance

Cutting

Speed

Pierce

Height

Factor

200

H35

N2

H35

N2

H35

N2

H35

N2

mm

mm/m

%

seconds

6

156

2125

8

158

1875

10

159

1625

12

160

1375

0.5

15

162

1125

0.8

20

164

875

1.3

0

0

80

3.0

25

43

Torch-to-

Work

distance

0

31

65

3.5

0.3

200

Arc

Voltage

Cutting

Speed

Pierce

Height

Factor

Pierce

Delay

Plasma

Shield

Plasma

Shield

Test Preflow Rate (%)

Test Cutflow Rate (%)

Material

Thickness

millimeters

Advertising