INSTALLATION

3-12

HyPerformance HD4070

Instruction Manual

4070.14

Grounding requirements

Proper grounding is essential for personal safety and to prevent
emission of high-frequency interference. See

Grounding Safety in

Section 1 and Appendix A for system grounding requirements.

Connect the worktable to a high-quality earth ground, not more
than 6 m (20 feet) from the table. A suitable ground consists of a
solid copper rod of at least 13 mm (1/2 inch) diameter driven to a
depth of at least 2.5 m (8 feet) into the earth, below the permanent
moisture level. Ensure that all grounding connections are tight to
avoid excessive heating. Consult national or local electrical codes
for compliance and additional information.

Connect all HD4070 system components to earth ground. Use a minimum of 8 AWG (10 mm

2

) wire connected from

each component to the work table ground.

5

Gas console

Ignition console

Off-valve

4070.51