OPERATION

4-30

HyPerformance HD4070

Instruction Manual

Changing consumable parts

Remove consumables

Check the consumable parts daily for wear before cutting. Before removing consumables, bring the torch to the
edge of the cutting table, with the torch lifter raised to its highest point to prevent the consumables from dropping
into the water of the water table.

WARNING

The system is designed to go into an idle mode if the retaining cap is removed. However, DO NOT
CHANGE CONSUMABLE PARTS WHILE IN THE IDLE MODE! Always disconnect power to the power
supply before inspecting or changing torch consumable parts. Use gloves when removing
consumables. The torch might be hot.

Turn OFF all power to the system.

Remove retaining cap
and shield

Remove inner
retaining cap

Remove
electrode

Remove nozzle
and swirl ring

Tool part number

104119