Inspect consumables -31, Part check for action – Hypertherm HD4070 Rev.1 User Manual

Page 156

Advertising
background image

OPERATION

HyPerformance HD4070

Instruction Manual

4-31

Inspect Consumables

Part

Check for

Action

Retaining cap

Nozzle

Swirl ring

Electrode

Center surface

Wear

O-rings

1. Damage

Replace electrode*

2. Lubricant

Apply a thin film of silicone lubricant if dry

*Note:

Always replace the nozzle and electrode as a set.

Damage

Replace swirl ring

Dirt or debris

Clean and check for damage, and replace swirl ring
if damaged

Gas holes

Blocked holes

Replace swirl ring

O-rings

1. Damage

Replace swirl ring

2. Lubricant

Apply a thin film of silicone lubricant if dry

Center hole

1. Must be round

Replace nozzle if hole is no longer round*

2. Signs of arcing

Replace nozzle*

O-rings

1. Damage

Replace nozzle*

2. Lubricant

Apply a thin film of silicone lubricant if dry

Erosion or missing material

Replace nozzle*

Blocked gas holes

Replace nozzle*

Erosion, missing material

Replace cap

Cracks

Replace cap

Burns

Replace cap

See

Inspect Electrode Pit Depth later

in this section