background image

2-TORCH INSTALLATION

HyPerformance HD4070

Instruction Manual

3B-23

4070_11A

Torch

Torch

2 4 a

2 4 b

2 6

2 5 b

2 5 a

Install the torch and lead
assembly

Lead assemblies

24

Part no.

Length

128890

1.8 m (6 ft)

128891

3.0 m (10 ft)

128892

4.5 m (15 ft)

Plasma gas
vent hose

Torch # 1

Torch # 2

Installation note

Mark the torch number on the ends of
each gas hose and torch lead.

Torch assembly – 228048

25

Torch receptacle plug – 129982

26

Plasma gas
vent hose

Caution:

Locate the exposed end of the plasma gas vent hose away from
sparks caused by piercing to avoid ignition and possible damage to
the torch leads