System operation screens -11, System operation screens 4 – Hypertherm HD4070 Rev.1 User Manual

Page 136

Advertising
background image

OPERATION

HyPerformance HD4070

Instruction Manual

4-11

TORCH 1

PURGING

STAINLESS STEEL

AUTO
MAN
THC

ARC
VOLT

ARC
VOLT

3/4 IN

200 AMPS

++

_ _

13

CNC

TORCH 1

NO PILOT ARC

STAINLESS STEEL

AUTO
MAN
THC

ARC
VOLT

ARC
VOLT

3/4 IN

200 AMPS

++

_ _

13

CNC

TORCH 1

READY

STAINLESS STEEL

AUTO
MAN
THC

ARC
VOLT

ARC
VOLT

3/4 IN

200 AMPS

++

_ _

13

NEXT

NEW

PROCESS

NEXT

NEW

PROCESS

NEXT

NEW

PROCESS

TRAVEL SPEED: 84 IPM

INLET GAS: O2 N2

CUT HEIGHT: 0.180 IN

SET ARC VOLTS: 161.0 V

TRAVEL SPEED: 84 IPM

INLET GAS: O2 N2

CUT HEIGHT: 0.156 IN

SET ARC VOLTS: 144.0 V

TRAVEL SPEED: 84 IPM

INLET GAS: O2 N2

CUT HEIGHT: 0.156 IN

SET ARC VOLTS: 144.0 V

System operation screens

4

When screen 13 first appears, the system will
purge all gas lines.

After the gases are purged, the screen will display
READY indicating that the power supply is ready to
receive the start signal from the CNC.

Screen 13 provides process information so that the
operator can view what parameters are being used.

Error codes are displayed at the top of the screen.
The system will clear some error codes and will then
return to the READY state. When an error occurs
that freezes the system software, a RESET button
appears in place of NEW PROCESS. Pushing
RESET clears the error without having to turn the
power off.

See

Maintenance Section 5 for a complete list of

error codes and corrective actions.

Display will advance to screen 14.