OPERATION

HyPerformance HD4070

Instruction Manual

4-21

Mild steel

O

2

Plasma / O

2

-N

2

Shield

130A Cutting

Pierce height = torch-to-work distance X pierce height factor

220173

220183

220176

220182

220179

220181

Metric

English

O2

N2

O2

N2

O2

N2

O2

N2

in

ipm

%

seconds

10/.135

124

0.100

240

0.1

3/16

126

190

0.2

1/4

127

150

5/16

129

130

3/8

130

110

7/16

131

95

0.4

1/2

132

80

0.5

9/16

134

70

0.6

5/8

135

60

0.7

40

90

3/4

140

45

1.0

12

35

19

58

200

0.3

0.110

0.120

0.130

0.150

Plasma

Shield

18

55

16

48

70

0

Cutting

Speed

Pierce

Height

Factor

Pierce

Delay

Test Preflow Rate (%)

Test Cutflow Rate (%)

Material

Thickness

gauge/inch

Arc

Voltage

Torch-to-

Work

distance

Plasma

Shield

O2

N2

O2

N2

O2

N2

O2

N2

mm

mm/m

%

seconds

3

124

2.5

6400

0.1

4

126

5425

0.2

5

127

4700

6

127

3975

8

129

3325

10

130

2650

12

132

3.2

2175

0.5

15

135

1650

0.7

40

90

20

140

1025

1.0

200

0.3

2.7

3.0

3.7

16

48

12

35

70

0

19

58

18

55

Test Preflow Rate (%)

Test Cutflow Rate (%)

Material

Thickness

millimeters

Arc

Voltage

Plasma

Shield

Plasma

Shield

Torch-to-

Work

distance

Cutting

Speed

Pierce

Height

Factor

Pierce

Delay

Advertising