Supply gas plumbing -13, Connect the supply gases -13, Supply gas plumbing – Hypertherm HD4070 Rev.1 User Manual

Page 65: 6connect the supply gases, Warning, Inlet gases

Advertising
background image

INSTALLATION

HyPerformance HD4070

Instruction Manual

3-13

Supply gas plumbing

Rigid copper plumbing or suitable flexible hose may be used for all gas supplies. Do not use steel or aluminum
pipe.
After installation, pressurize the entire system and check for leaks.
Recommended hose diameters are 9.5 mm (3/8 inch) for lengths < 23 m (75 feet) and 12.5 mm (1/2 inch) for
lengths > 23 m (75 feet).

For flexible-hose systems, use a hose designed for inert gas to carry air, nitrogen, or argon-hydrogen.

6

Connect the supply gases

Connect the supply gases to the HD4070 gas console. Torch leads must be purged between gas changes.

WARNING

CUTTING WITH OXYGEN CAN CAUSE FIRE OR EXPLOSION

Cutting with oxygen as the plasma gas can cause a potential fire hazard due to the oxygen-enriched
atmosphere that it creates. As a precaution, Hypertherm recommends that an exhaust ventilation
system be installed when cutting with oxygen.

Fitting

Size

H35, H5 &

9/16 – 18 LH,

F5

(Fuel Gas)”B”

O

2

9/16 – 18, RH
(oxygen) “B”

N

2

5/8 – 18, RH, internal
(Inert Gas) “B”

Air

9/16 – 18 #6

CO

2

Inlet Gases

H35

AIR

H5

F5/CH

4

O

2

N

2

4070.12

2

6

Note:

When cutting with oxygen as the plasma gas, nitrogen must also be connected to
the gas console to achieve the proper oxygen-nitrogen mixtures in the preflow and
cutflow conditions.

Caution:

When configuring the gas console to the supply gases, make sure that all
hoses, hose connections and fittings are acceptable for use with oxygen,
argon-hydrogen and methane. Installation must be made in accordance with
local or national codes.

Advertising