background image

INSTALLATION

HyPerformance HD4070

Instruction Manual

3-19

Notes: to CNC interface cable run list

Note 1.

Motion and Transfer Outputs.
Relay Contact Closure.

Note 2.

HD4070 outputs are optically coupled
transistors with maximum ratings of
24 VDC and 10 mA.

Note 3.

HD4070 inputs are optically isolated 12 VDC
signals. Signals are made active by sinking
3 mA per input.

Note 4.

Emergency interlock contact closure.

∗ Normally closed

+

-

Machine Interf

ace

Receptacle

Relay

Relay

+ 24 VDC

10 mA

24 V return

Output

Output

Input

External emergency interlock

Install NC

switch or
jumper

HD4070 control box – enclosure

12 V Return

12 VDC

4.7 K

24 VDC maximum
10 mA maximum

Pin 37

Pin 19