Torch coolant draining -6, Power supply coolant draining -6, Torch coolant draining – Hypertherm HD4070 Rev.1 User Manual

Page 169: Power supply coolant draining

Advertising
background image

5-6

HyPerformance HD4070

Instruction Manual

MAINTENANCE

Torch coolant draining

If the torch needs to be changed or transported, follow this procedure for draining the torch coolant from the torch
and torch leads. Coolant should be drained from the system every 6 months. See

Preventative Maintenance

Schedule at the back of this section.

1. Disconnect all power to the HD4070 system.

2. Disconnect the torch leads from the ignition console and valve cluster.

3. Ensure that the consumables are installed in the torch.

4. Position the torch lead fittings over a drain or other suitable device to collect coolant.

5. Blow clean, dry, oil-free air at 5.5-8.3 bar (80-120 psi) into the hose with the green band.

Coolant will flow out of hose with the red band.

Power supply coolant draining

If the power supply needs to be transported, follow this procedure to drain the coolant from the system. Coolant
should be drained from the system every 6 months. See

Preventative Maintenance Schedule at the back of this

section.

1. Disconnect all power to the HD4070 system.

2. Disconnect and drain the coolant from the hoses going between the water cooler and the ignition console.

3. Place a suitable receptacle under the coolant system’s drain petcock. See figure below.

4. Turn petcock counterclockwise to drain coolant.

Coolant drain location