Encryption, Encryption -89 – Verilink WANsuite 5165 (34-00301.H) Product Manual User Manual

Page 119

Advertising
background image

W e b S e r v e r I n t e r f a c e

3-89

Figure 3.90

SMTP Details Screen

Mail Server IP Address

IP address of the mail server to which notifications will be sent.

Domain Name

Name of domain where the device resides (i.e., Verilink.com)

Mail From

E-mail address of the device (WANsuite). While the device will not be able to
retrieve e-mail from a service, the mail needs to have the “From” address
filled in.

NOTICE:

There can be no blank space(s) in the “Mail From” address.

Recipient 1...5

E-mail addresses of recipients of event notifications (i.e., [email protected]
or [email protected]).

Encryption

If a DLCI encapsulation is set for FRF.17 instead of RFC1490, all data will
be encrypted using FRF.17 Mode One formats and protocols. However, the
encryption method is Blowfish, rather than the DES specified in FRF.17.

NOTICE:

This software-based encryption should not affect performance of the
unit in a SCADA environment because the message size is quite small.
However, a main site unit encrypting up to 128 DLCIs and operating a
number of remote units using encryption will see a degradation in
performance as traffic increases.

Advertising