W e b S e r v e r I n t e r f a c e

3-11

Serial Screens

NOTICE:

All references in this manual to the Serial 1 and Serial 2 interfaces
correspond directly to the WANsuite 5165’s Data 1 and Data 2 ports,
respectively.

The parameters on all Serial screens are the same except for the Invert Clock
parameter, which is found only on the Serial 2 screen; therefore, only the
Serial 2 screen (Figure 3.9) is shown below.

Figure 3.9

Serial 2 Screen

Type

This parameter selects the type of interface (based on its electrical signal
characteristics) used by the equipment connected to the Serial port.

Values: V.35, RS-232, EIA-530
Default: V.35

NOTICE:

V.35 requires the use of an optional cable. Refer to Optional Equipment
on page A-6 f
or ordering information.

Mode

By default, the Serial port serves as a DCE port in both Packet and TDM
modes. However, the Serial port can serve as a DTE port when the unit is in
Packet mode.

If the Serial port connects to a DTE device (such as a FRAD or a router), the
Mode parameter must be set to “DCE.” If this port connects to a DCE device
(such as a DSU/CSU), this parameter must be set to “DTE” (valid only for
Packet mode, not TDM).

Values: DCE, DTE
Default: DCE