W e b S e r v e r I n t e r f a c e

3-55

%EFS

Displays the percentage of time that the test ran error-free. This ratio is
derived from the number of error free seconds divided by the number of
seconds accumulated in Elapsed Time.

Loop Table on the Network Interface Test Details Screen

The Loop Table at the bottom of the screen lets you specify the type of Loop
test to be performed. The types of tests available for the Network interface are
shown below. Loopback diagrams are illustrated in Appendix A, Figure A.1.

Values: No Test (Loop Down), payload loopback (PLB), line loopback

(LLB), maintenance loopback (MLB), Far PLB, Far LLB

Default: No Test (Loop Down)

Figure 3.48

Serial Interface Test Details Screen

BERT Table on the Serial Interface Test Details Screen

The BERT table lets you set the test parameters listed below.

Setting

Displays the bandwidth on which you wish to perform the BERT. The
available values for this parameter depend on which interface is selected.

Values: Net, DTE
Default: Net

BERT Pattern

Specifies the pattern to be transmitted during a test for the selected port.

Values: Marks, QRSS, 511, 2047, 2

15

, Spaces

Default: QRSS

NOTICE:

The 2

15

pattern is the ITU (European) version, not the ANSI version.

Test Duration

Specifies the length of time for which the test should run for the selected port.

Values: 15 minutes, 30 minutes, 1 hour, 24 hours, Continuous
Default: 15 minutes