3-28

W A N s u i t e 5 1 6 5

Default CIR (bps)

This is the Committed Information Rate (in bits per second) provided by your
frame relay service provider. The unit will apply this value to each DLCI
learned from the network side to gather statistics and to perform CIR
enforcement, if required. If a DLCI is configured with a CIR different from
the default, the DLCI configuration will be used instead.

Values: 0–1536000
Default: 0

Default Be Rate (bps)

This is the Excess Burst Rate (in bits per second) provided by your frame
relay service provider. The unit will apply this value to each DLCI learned
from the network side to gather statistics and to perform CIR enforcement, if
required. If a DLCI is configured with an Excess Burst different from the
default, the DLCI configuration will be used instead.

Values: 0–1536000
Default: 0

Enforce CIR and Be

If this parameter is set to “Yes,” the unit will enforce Committed Information
Rate and Excess Burst according to the Link Injection Parameter.

Values: No, Yes
Default: No

NOTICE:

The Auto Diagnostic parameter must be set to “Yes” to enforce CIR and
Be.

Management DLCI

If there is a DLCI entered (and submitted) in this field, it will be the only
DLCI that looks for in-band management packets. If a value of “0” (zero) is
entered in this field, all DLCIs will look for management packets.

Management Auto IP

DLCI

If this parameter is set to “Yes,” the unit will monitor the specified
management DLCI for 5 pings over 5 seconds, after which the unit uses the
destination address as its management IP address.

FrameStart Auto

Diagnostic

When this parameter is set to “Yes,” the unit will always source LMI on both
sides of the frame relay connection. The unit will dynamically learn the type
of link management used on each side of the connection (Network or Serial).

When set to “No,” the unit will monitor LMI between the Serial and the
Network port. If one side of the connection goes down, it will source LMI
until the connection goes back up, and will automatically go back to Monitor
mode once both sides are up. In Monitor mode, the unit will switch all frames
received between the network and the serial port regardless of the number of
DLCIs or frame size.

FrameStart Auto Diagnostic mode should be left set to “Yes” unless the frame
relay connection has more that 128 DLCIs, or if there is a very high traffic
rate on a constant basis.

Values: No, Yes
Default: Yes