Network configuration screens, Network configuration screens -7 – Verilink WANsuite 5165 (34-00301.H) Product Manual User Manual

Page 131

Advertising
background image

V T 1 0 0 I n t e r f a c e

4-7

From the Interfaces screen, you may choose from the following: Network 1,
Network 2, Serial 1, Serial 2, 10/100 Ethernet, or Supervisory.

Network Configuration Screens

The WANsuite 5165 Network screens let you view and make changes to the
Network interface's configuration. In addition, the screens provide a table that
displays the alarm values for Network interfaces. The Network 1 and Network
2 screens are the same except for the “Function” parameter, which is found
only on the Network 2 screen (Figure 4.7). Network parameters are described
below.

Figure 4.7

Network 2 Config Screen

Function (Network 2

Only)

In the “Slaved” function, Network 2 is slaved and can only be mapped to
Network 1. In the Network function, Network 2 functions as an independent
network, but can only be mapped to Serial 2.

Values: Slaved, Network
Default: Slaved

NOTICE:

The “Function” parameter fundamentally affects the operation of the
unit. Even though this parameter is found only on the Network 2 Config
screen, its setting affects both Network ports and the Service table.

Framing

Selects the framing for the Network side of the DSU/CSU.

Values

ESF, D4

Default: ESF

Line Coding

Sets the Network side line coding.

Values: B8ZS, AMI
Default: B8ZS

PRM Enable

Lets you establish which performance messaging standard will be employed
to initiate Performance Report Message (PRM) functions. Setting this field to

Advertising