Data line monitor configuration table, Data line monitor configuration table -20 – Verilink WANsuite 5165 (34-00301.H) Product Manual User Manual

Page 144

Advertising
background image

4-20

W A N s u i t e 5 1 6 5

Figure 4.15

Service Table Screen

The Status for a particular service will display as one of the following:

Dead

The service is not functional because required resources are not

available.

Changed

The service parameter was changed and a Save and Restart is

required for the service to function.

Down

The service is not able to pass data because the physical layer is

down.

Physical Up

The service is not able to pass data because it has not

completed any required negotiations.

Up

The service is ready to pass data.

Idle

The service has nothing to do.

The Service Table screen displays the available services listed by Index
number. To view more detailed information about a service, navigate to one of
the Details screen (such as the Service Details screen described on page 4-23)
by selecting from an entry under the “Index” column (Service Details), the
<Interface> column (Interface Details), or <Type> column (Type Details). To
add a service, select the “Add Service prompt at the top of the screen.

Data Line Monitor Configuration Table

Select the Data Line Monitor prompt at the top of the Service Table screen to
view a screen that displays SCADA port information (Figure 4.16).

Advertising