Full sequence, Interrupting program run – HEIDENHAIN NC 124 User Manual
Page 105
![background image](/files/815891/content/doc105.png)
10
Executing Programs
TNC 124
105
Full sequence
The machine manufacturer determines whether or not
the Full Sequence function is enabled on your TNC.
Operating mode: PROGRAM RUN
If PROGRAM RUN SINGLE BLOCK is displayed at the top of the screen,
go to Automatic.
Position.
NC
The TNC automatically executes the next positioning block as soon
as it has reached the programmed position.
Interrupting program run
Interrupt program run, but do not abort:
ä Press NC
-0
.
To resume program run after an interruption:
ä Press NC
-I
.
Stop program run and abort:
ä Press NC
-0
.
The soft-key row contains the soft key INTERN. STOP.
ä Press INTERN. STOP.
To restart program run after STOP
The TNC interrupts program run as soon as it reaches a STOP
block.
To restart program run:
ä Press NC
-I
.
If re-
quired: