Calling datum points
The TNC 124 can store up to 99 datum points in a datum table. You
can call a datum point from the datum table during program run by
simply pressing the soft key Datum Call and entering the block
DATUM XX.
This automatically calls the datum point entered for XX
during program run.
Operating mode: PROGRAMMING AND EDITING
Go to the third soft-key row.
Call a datum point from the table.
/
D a t u m n u m b e r ?
Enter the datum number (such as 5).
Confirm entry. Input range: 1 to 99.
5
ENT