EtherNet/IP 3-2

Supported Output Instances

‹

Basic Speed Control Output Instance 20 (14h)

Run Forward:

Forward RUN Command

Fault Reset:

Fault Reset Command

Speed reference:

RPM when o1-03 = (2 ~ 39)

‹

Extended Speed Control Output Instance 21 (15h)

Run Forward:

Forward RUN Command

Run Reverse:

Reverse RUN Command

Fault Reset:

Fault Reset Command

Net Control:

Parameter b1-02

0 - 1 transition sets b1-02 = 3
1 - 0 transition sets b1-02 to previous value

Net Reference:

Parameter b1-01
0 - 1 transition sets b1-01 = 3
1 - 0 transition sets b1-01 to previous value

Speed Reference:

RPM when o1-03 = (2 ~ 39)

Output

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Instance

0

-

-

-

-

-

Fault

Reset

-

Run

Forward

20

1

-

2

Speed Reference (Low Byte) [scaled by parameter o1-03]

3

Speed Reference (High Byte) [scaled by parameter o1-03]

Output

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Instance

0

-

Net

Reference

Net

Control

-

-

Fault

Reset

Run

Reverse

Run

Forward

21

1

-

2

Speed Reference (Low Byte) [scaled by parameter o1-03]

3

Speed Reference (High Byte) [scaled by parameter o1-03]