Class 6dh, instance 1 - terminal object – Yaskawa CM092 User Manual

Page 71

Advertising
background image

Product Codes & Parameter Tables 5-14

‹

Class 6Dh, Instance 1 - Terminal Object

HX-XX parameters all share the same service (GET/SET), data type (Word) and number of bytes (2)

Parameter

Name

Attribute [hex]

F7U

G7U

P7U

E7U

G5M

H1-01

Terminal S3 Function Selection

1

1

1

1

1

H1-02

Terminal S4 Function Selection

2

2

2

2

2

H1-03

Terminal S5 Function Selection

3

3

3

3

3

H1-04

Terminal S6 Function Selection

4

4

4

4

4

H1-05

Terminal S7 Function Selection

5

5

5

5

5

H1-06

Terminal S8 Function Selection

6

6

6

H1-07

Terminal S9 Function Selection

7

H1-08

Terminal S10 Function Selection

8

H1-09

Terminal S11 Function Selection

9

H1-10

Terminal S12 Function Selection

10

H2-01

Terminal M1-M2 Function Selection

12 (0Ch)

12 (0Ch)

12 (0Ch)

12 (0Ch)

7

H2-02

Terminal P1 Function Selection

13 (0Dh)

13 (0Dh)

13 (0Dh)

13 (0Dh)

8

H2-03

Terminal P2 Function Selection

14 (0Eh)

14 (0Eh)

9

H2-04

Terminal P3 Function Selection

15 (0Fh)

H2-05

Terminal P4 Function Selection

16 (10h)

H3-01

Terminal A1 Signal

17 (11h)

17 (11h)

10 (0Ah)

H3-02

Terminal A1 Gain %

18 (12h)

18 (12h)

18 (12h)

18 (12h)

11 (0Bh)

H3-03

Terminal A1 Bias %

19 (13h)

19 (13h)

19 (13h)

19 (13h)

12 (0Ch)

H3-04

Terminal A3 Level

20 (14h)

20 (14h)

13 (0Dh)

H3-05

Terminal A3 Selection

21 (15h)

21 (15h)

14 (0Eh)

H3-06

Terminal A3 Gain %

22 (16h)

22 (16h)

15 (0Fh)

H3-07

Terminal A3 Bias %

23 (17h)

23 (17h)

16 (10h)

H3-08

Terminal A2 Level

24 (18h)

24 (18h)

24 (18h)

24 (18h)

17 (11h)

H3-09

Terminal A2 Selection

25 (19h)

25 (19h)

25 (19h)

25 (19h)

18 (12h)

H3-10

Terminal A2 Gain %

26 (1Ah)

26 (1Ah)

26 (1Ah)

26 (1Ah)

19 (13h)

H3-11

Terminal A2 Bias %

27 (1Bh)

27 (1Bh)

27 (1Bh)

27 (1Bh)

20 (14h)

H3-12

Filter Average Time Sec

28 (1Ch)

28 (1Ch)

28 (1Ch)

28 (1Ch)

21 (15h)

H3-13

TA1/TA2 Selection

29 (1Dh)

29 (1Dh)

H4-01

Terminal FM Selection

30 (1Eh)

30 (1Eh)

30 (1Eh)

30 (1Eh)

22 (16h)

H4-02

Terminal FM Gain

31 (1Fh)

31 (1Fh)

31 (1Fh)

31 (1Fh)

23 (17h)

H4-03

Terminal FM Bias %

32 (20h)

32 (20h)

32 (20h)

32 (20h)

24 (18h)

H4-04

Terminal AM Selection

33 (21h)

33 (21h)

33 (21h)

33 (21h)

25 (19h)

H4-05

Terminal AM Gain %

34 (22h)

34 (22h)

34 (22h)

34 (22h)

26 (1Ah)

H4-06

Terminal AM Bias %

35 (23h)

35 (23h)

35 (23h)

35 (23h)

27 (1Bh)

H4-07

AO Level Selection

36 (24h)

36 (24h)

36 (24h)

36 (24h)

28 (1Ch)

H4-08

AO Level Selection 2

37 (25h)

37 (25h)

37 (25h)

37 (25h)

H5-01

Serial Communication Address

38 (26h)

38 (26h)

38 (26h)

38 (26h)

29 (1Dh)

H5-02

Serial Baud Rate

39 (27h)

39 (27h)

39 (27h)

39 (27h)

30 (1Eh)

H5-03

Serial Communication Parity Selection

40 (28h)

40 (28h)

40 (28h)

40 (28h)

31 (1Fh)

H5-04

Serial Communication Fault Selection

41 (29h)

41 (29h)

41 (29h)

41 (29h)

32 (20h)

H5-05

Serial Communication Fault Detection

42 (2Ah)

42 (2Ah)

42 (2Ah)

42 (2Ah)

33 (21h)

H5-06

Serial Communication Transmit Wait Time ms

43 (2Bh)

43 (2Bh)

43 (2Bh)

43 (2Bh)

H5-07

RTS Control Selection

44 (2Ch)

44 (2Ch)

44 (2Ch)

44 (2Ch)

Advertising