Class 6eh, instance 1 - protection object – Yaskawa CM092 User Manual

Page 72

Advertising
background image

Product Codes & Parameter Tables 5-15

‹

Class 6Dh, Instance 1 - Terminal Object (Continued)

‹

Class 6Eh, Instance 1 - Protection Object

LX-XX parameters all share the same service (GET/SET), data type (Word) and number of bytes (2)

Parameter

Name

Attribute [hex]

F7U

G7U

P7U

E7U

G5M

H5-08

Communication Protocol Selection

53 (35h)

H5-09

Communication Error Detection Time

54 (36h)

54 (346)

H6-01

Pulse Input Selection

45 (2Dh)

45 (2Dh)

H6-02

Pulse Input Selection

46 (2Eh)

46 (2Eh)

H6-03

Pulse Input Scaling Hz

47 (2Fh)

47 (2Fh)

H6-04

Pulse Input Gain %

48 (30h)

48 (30h)

H6-05

Pulse Input Bias %

49 (31h)

49 (31h)

H6-06

PI Filter Time Sec

50 (32h)

50 (32h)

H6-07

Pulse Output Selection

51 (33h)

51 (33h)

Parameter

Name

Attribute [hex]

F7U

G7U

P7U

E7U

G5M

L1-01

Motor Overload Fault Selection

1

1

1

1

1

L1-02

Motor Overload Time Constant Minimum

2

2

2

2

2

L1-03

Motor Overheat Alarm Operation Selection

3

3

3

3

L1-04

Motor Overload Filter Time Sec

4

4

4

4

L1-05

Motor Overheat Filter Time

5

5

5

5

L2-01

Power Loss Ride Through Selection

6

6

6

6

3

L2-02

Power Loss Ride Through Time

7

7

7

7

4

L2-03

Power Loss Ride Through Baseblock Time

8

8

8

8

5

L2-04

Power Loss Ride Through V/F Ramp Time Sec

9

9

9

9

6

L2-05

Undervoltage (UV1) Detection Level VDC

10 (0Ah)

10 (0Ah)

10 (0Ah)

10 (0Ah)

7

L2-06

KEB Frequency %

11 (0Bh)

11 (0Bh)

8

L2-07

Undervoltage Recovery Time Sec

12 (0Ch)

12 (0Ch)

L2-08

KEB Decel Time %

13 (0Dh)

13 (0Dh)

L3-01

Stall Prevention Accel Selection

16 (10h)

16 (10h)

16 (10h)

16 (10h)

9

L3-02

Stall Prevention Accel Level %

17 (11h)

17 (11h)

17 (11h)

17 (11h)

10 (0Ah)

L3-03

Stall Prevention Constant Horsepower Level %

18 (12h)

18 (12h)

18 (12h)

18 (12h)

11 (0Bh)

L3-04

Stall Prevention Decel Selection

19 (13h)

19 (13h)

19 (13h)

19 (13h)

12 (0Ch)

L3-05

Stall Prevention Run Selection

20 (14h)

20 (14h)

20 (14h)

20 (14h)

13 (0Dh)

L3-06

Stall Prevention Run Level %

21 (15h)

21 (15h)

21 (15h)

21 (15h)

14 (0Eh)

L3-11

Overvoltage Inhibit Selection

72 (48h)

72 (48h)

L3-12

Overvoltage Inhibit Voltage Level

73 (49h)

73 (49h)

L4-01

Speed Agree Level Hz

26 (1Ah)

26 (1Ah)

26 (1Ah)

26 (1Ah)

17 (11h)

L4-02

Speed Agree Width Hz

27 (1Bh)

27 (1Bh)

27 (1Bh)

27 (1Bh)

18 (12h)

L4-03

Speed Agree Level +/- Hz

28 (1Ch)

28 (1Ch)

19 (13h)

L4-04

Speed Agree Width +/- Hz

29 (1Dh)

29 (1Dh)

20 (14h)

L4-05

Reference Loss Selection

30 (1Eh)

30 (1Eh)

30 (1Eh)

30 (1Eh)

21 (15h)

L4-06

Frequency Reference At Frequency Loss

67 (43h)

67 (43h)

67 (43h)

67 (43h)

Advertising
This manual is related to the following products: