Speed and torque control input instance 72 (48h) – Yaskawa CM092 User Manual

Page 36

Advertising
background image

EtherNet/IP 3-7

‹

Speed and Torque Control Input Instance 72 (48h)

Note:

1

F7U, G7U and G5M in FVC mode only

Faulted:

Drive Fault

Running 1 (Forward): Running in forward direction
Speed Actual:

RPM if o1-03 = (2 ~ 39)

Torque Actual:

Percent of rated torque

‹

Extended Speed and Torque Control Input Instance 73 (49h)

Note:

1

F7U, G7U and G5M in FVC mode only

Faulted:

Drive Fault

Warning:

Drive Alarm

Running 1 (Forward): Running in forward direction
Running 1 (Reverse): Running in reverse direction
Ready:

Drive Ready

Control from Net:

0 = Non-network control
1 = Control from network

Reference from Net:

0 = Reference not from network
1 = Reference from network

At Speed:

Speed Agree

Speed Actual:

RPM if o1-03 = (2 ~ 39)

Torque Actual:

Percent of rated torque

Input

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Instance

0

-

-

-

-

-

Running 1

(FWD)

-

Faulted

72

1

-

2

Speed Actual (Low Byte) [scaled by parameter o1-03

3

Speed Actual (High Byte) [scaled by parameter o1-03]

4

Torque Actual

1

(Low Byte) [0.1%]

5

Torque Actual

1

(High Byte) [0.1%]

Input

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Instance

0

At Speed

Reference

from Net

Control

from Net

Ready

Running 2

(REV)

Running 1

(FWD)

Warning

Faulted

73

1

-

2

Speed Actual (Low Byte) [scaled by parameter o1-03

3

Speed Actual (High Byte) [scaled by parameter o1-03]

4

Torque Actual

1

(Low Byte) [0.1%]

5

Torque Actual

1

(High Byte) [0.1%]

Advertising