EtherNet/IP 3-16

‹

Class 29h – Control Supervisor Object

Attributes

Note:

1

See Fault Code Conversions at the end of this section.

Service Code No. (hex)

Service Name

0E

Get Attribute Single

10

Set Attribute Single

05

RESET

Instance ID

Attribute

Description

Get

Set

Size

V7 Data

0

1

Object Software Revision

X

-

Word

1

1

3h

Run 1 (Forward Run)

X

X

Byte

Forward Run Command

4h

Run 2 (Reverse Run)

X

X

Byte

Reverse Run Command

5h

Net Control

X

X

Byte

Net Control Command - Parameter b1-02

6h

State

X

-

Byte

Inverter Status

7h

Running 1 (Forward)

X

-

Byte

Forward Running

8h

Running 2 (Reverse)

X

-

Byte

Reverse Running

9h

Ready

X

-

Byte

Inverter Ready

10 (0Ah)

Faulted

X

-

Byte

Inverter Fault

11 (0Bh)

Warning

X

-

Byte

Inverter Alarm

12 (0Ch)

Fault Reset

X

X

Byte

Fault Reset

13 (0Dh)

Fault Code

X

-

Word

Current Fault

1

14 (0Eh)

Warn Code

X

-

Word

Current Warning

15 (0Fh)

Control from Net

X

-

Byte

Net Control Status - Parameter b1-02

16 (10h)

CIP Fault Mode

X

-

Byte

Always “2”

17 (11h)

Force Fault

X

X

Byte

External Fault - EF0

18 (12h)

Force Status

X

-

Byte

External Fault Status - EF0