Class 65h - yaskawa status object – Yaskawa CM092 User Manual

Page 49

Advertising
background image

EtherNet/IP 3-20

* The type of physical outputs and their terminal designations for outputs controlled by bits 0 and 1 differ according to the drive. Refer to the
appropriate drive user, programming and/or technical manual for details on digital outputs.

‹

Class 65h - Yaskawa Status Object

Attributes

* Parameter o2-04 for kVA model - Scaling is 0.01A for kVA models 00h ~ 06h and 20h ~ 26h

Yaskawa Command Object – Class 64h, Instance 1, Attribute 8 – Digital Output

Bit

Definition

0

PHC 1 – Multi-function Digital Output 1 – Parameter H2-01 setting*

1

PHC 2 – Multi-function Digital Output 2 – Parameter H2-02 setting*

2

Reserved

3

Reserved

4

Reserved

5

Reserved

6

Fault Contact Enable

7

Fault Contact – Bit 6 must be set to 1 in order to enable the function of bit 7

Service Code No. (hex)

Service Name

0E

Get Attribute Single

10

Set Attribute Single

Instance ID

Attribute

Description

Get

Set

Size

Default Value

0

1

Object software Revision

X

Word

1

1

1

Drive Status

X

Word

0

2

Speed Feedback (o1-03 scaled)

X

Word

0

3

Torque Reference (0.1%)

X

Word

0

4

Speed Detection PG Count

X

Word

0

5

Speed Reference (o1-03 scaled)

X

Word

0

6

Output Frequency (o1-03 scaled)

X

Word

0

7

Output Current*

X

Word

0

8

Analog Input Channel 2

X

Word

0

9

DC bus Voltage (1V)

X

Word

0

10 (0Ah)

Fault Code 1

X

Word

0

11 (0Bh)

Fault Code 2

X

Word

0

12 (0Ch)

Fault Code 3

X

Word

0

13 (0Dh)

Analog Input Channel 3 (F7U/G7U only)

X

Word

0

14 (0Eh)

Digital Input 2

X

Word

0

15 (0Fh)

Analog Input Channel 1

X

Word

0

16 (10h)

Channel 2 PG Counter

X

Word

0

Advertising
This manual is related to the following products: