6 DEBUGGING

6.1.1 Display Current Values

6-2

6.1 BASIC FUNCTION

The following functions are valid for monitoring/debugging.

• Current value display
• SYNC function
• HOLD function (supported in the future)

6.1.1 Display Current Values

In the online mode, the current values can be displayed at the same time as the program dis-
played. The current values are renewed constantly and the newest data will be displayed.
The current value of each instruction is as follows.

„

Contact

The open/close status of a contact is displayed in the program. The close status is distin-
guished from the different color.

„

Coil

The energized/de-energized status of a coil is displayed in the program. The energized status
is distinguished from the different color.

Advertising