6.1 BASIC FUNCTION

6-3

6

„

Operand

The value of the operand for an operation is displayed below the format.

Select Tool (T) - Editor Option (E) of the menu to set the color.

6.1.2 SYNC

The SYNC is available in only the on-line mode. Its operation is disabled in the off-line mode.

The current values of a program at the time at which the specified register (S, I, O, M, D, C, #)
or a subscript register I or J takes on certain value or when the ON/OFF condition of a desig-
nated relay No. is satisfied can be displayed. The current value display is renewed when the des-
ignated condition is satisfied and will remain the same if condition is not satisfied. Up to 2
synchronization conditions may be set. If two conditions are set, an AND condition is used.

1. Select Debug (D) - SYNC (S) of the menu.