TA Triumph-Adler P-C2660i MFP User Manual

Page 346

Advertising
background image

10-10

Troubleshooting > Solving Malfunctions

Printouts have black lines.

Is the slit glass dirty?

Clean the slit glass.

10-6

Run [Laser Scanner Cleaning].

9-29

Images are skewed.

Are the originals placed correctly?

When placing originals on the platen,
align them with the original size
indicator plates.

3-10

When placing originals in the
document processor, align the original
width guides securely before placing
the originals.

3-11

Is the paper loaded correctly?

Check the position of the paper width
guides.

3-2

When displaying an image
sent from the machine on the
PC, an image size is shrunk
vertically or horizontally.

Have you selected 200 × 100dpi
Normal or 200 × 400dpi Super for the
scan resolution?

Select a scan resolution other than
200 × 100dpi Normal or 200 × 400dpi
Super when sending an image.

3-44

Offset occurs.

Run [Drum Refresh].

9-29

Increase the adjustment value for [MC]
setting. Increase the adjustment value
1 level at a time from the current value.
If there is no improvement after the
value is increased by 1 level, increase
by 1 level again. If there is still no
improvement, return the setting to the
original value.

9-29

Part of the image is
periodically faint or blurred.

Decrease the adjustment value for
[MC] setting. Decrease the adjustment
value 1 level at a time from the current
value. If there is no improvement after
the value is decreased by 1 level,
decrease by 1 level again. If there is
still no improvement, return the setting
to the original value.

9-29

Irregular horizontal lines
appear in the image.

Decrease the adjustment value for
[MC] setting. Decrease the adjustment
value 1 level at a time from the current
value. If there is no improvement after
the value is decreased by 1 level,
decrease by 1 level again. If there is
still no improvement, return the setting
to the original value.

9-29

The altitude is 1500 m or
higher and irregular
horizontal white lines appear
in the image.

Set Altitude Adjustment to [High 1]. If
there is still no improvement, change
the value to [High 2].

9-29

Symptom

Checkpoints

Corrective Actions

Reference

Page

Advertising
This manual is related to the following products: