Uniview IPC675LFW-AX4DUPKC-VG 5MP Outdoor Mini PTZ Active Deterrence Network Camera with Night Vision User Manual

Page 109

Advertising
background image

104

Choose an alarm output from the drop-down list. The number of alarm outputs available may vary

with camera model.

Configure alarm output parameters.

Item

Description

Alarm

Name

The default name is the alarm output channel ID. You can rename it as needed.

Default

Status

Choose the default status. The default is

N.O.

.

If the external alarm device is normally open (N.O.), choose

N.O.

.

If the external alarm device is normally closed (N.C.), choose

N.C.

.

Delay(s)

The duration of alarm output after the alarm is triggered. Set it as needed.

Relay

Mode

The default is

Monostable

.

Monostable: The circuit can only remain in one stable state. When a trigger pulse is applied, the circuit

switches to another state, and then automatically switches back to the original stable state. The circuit

will repeat the same actions when the next trigger pulse arrives.

Bistable: The circuit can remain in two stable states. When a trigger pulse is applied, the circuit switches

to another state, and remains in this state after the trigger pulse is removed. When the next trigger

pulse is applied, the circuit switches back to the other stable state and remains in that state.

NOTE!

Set relay mode to better adapt to third-party alarm devices such as alarm lights. Please set the relay mode

according to the trigger mode of the third-party alarm device.

On the

Output Schedule

page, select

Enable Plan

, and then set when the camera can output

alarms. By default, the schedule (plan) is disabled.

Two methods are available to make an arming schedule:

Draw a schedule

Advertising