Network diagnosis – Uniview IPC675LFW-AX4DUPKC-VG 5MP Outdoor Mini PTZ Active Deterrence Network Camera with Night Vision User Manual
Page 134

129
CAUTION!
Restarting the camera will interrupt the ongoing service.
Click
Restart
and then confirm to restart the device. You may set a schedule to reboot the camera
automatically at the set time.
Heater
Use the heater to eliminate water droplets on the lens in a high humidity environment.
(1) Enable Heater.
(2) Set
Remaining Heating Time
.
2.
Network Diagnosis
Go to
Setup
>
System
>
Maintenance
>
Network Diagnosis
.
Select NIC
NIC1 is the camera’s IP address.
IP/port filter
All: Capture all packets of the camera.
Specify: Capture packets of the specified port or IP.
Filter: Filter packets of the specified port or IP and capture other packets.
Custom Rules
Select
Custom Rules
and set the rules.
Click
Start Capture
to start capturing packets. After packet capture is finished, save data and view the
diagnosis.
Test network delay and packet loss rate
Test network connectivity by sending test packets to a test address.
Test Address: Must be a valid IP address or domain name.
Packet Size (Bytes): Size of test packets to be sent. Range: [64-65507]. Sometimes a high delay
may be caused by a large packet size. If the test failed, set a smaller packet size and then try
again.