background image

SJ200 Inverter

Conf

igur

ing

Dr
iv

e P

a

ra

m

e

ters

3–37

“B” Function

Run

Mode

Edit

Defaults

Func.

Code

Name /

SRW Display

Description

–FEF

(EU)

–FU

(USA)

Units

B080 [AM] analog signal

gain

Adjust of analog output at
terminal [AM],
range is 0 to 255

100.

100.

AM-Adj 00100%

B082 Start frequency adjust-

ment

Sets the starting frequency for
the inverter output, range is 0.5
to 9.9 Hz

0.5

0.5

Hz

fmin 0000.5Hz

B083 Carrier frequency

setting

Sets the PWM carrier (internal
switching frequency), range is
2.0 to 14.0 kHz

5.0

5.0

kHz

Carrier 0005.0

B084 Initialization mode

(parameters or trip
history)

Select the type of initialization
to occur, two option codes:
00... Trip history clear
01... Parameter initialization
02... Trip history clear and
parameter initialization

00

00

INIT Mode TRP

B085 Country code for initial-

ization

Select default parameter values
for country on initialization,
four options, option codes:
00... Japan version
01... Europe version
02... US version

01

02

INIT Slct USA

B086 Frequency scaling

conversion factor

Specify a constant to scale the
displayed frequency for D007
monitor, range is 0.1 to 99.9

1.0

1.0

Cnv Gain 0001.0

B087 STOP key enable

Select whether the STOP key
on the keypad is enabled, two
option codes:
00... enabled
01... disabled

00

00

STP Key ON