B–35 – Hitachi SJ200 Series User Manual

Page 249

Advertising
background image

SJ200 Inverter

Appendix B

B–35

Note 1:

Assume that the inverter current rating is 10000 (for B013/B213).

B130

Over-voltage
LADSTOP enable

R/W Pauses deceleration ramp when

DC bus voltage rises above
threshold level, in order to
avoid over-voltage trip.
Two option codes:
00... Disable
01... Enable

00A4h

0, 1

B140

Over-current trip
suppression

R/W Two option codes:

00... Disable
01... Enable

00A5h

0, 1

B150

Carrier mode (not
accessible to ModBus)

Automatically reduces the
carrier frequency as the
ambient temperature increases.
Two option codes:
00... Disable
01... Enable

00A6h

0, 1

“B” Group Fine Tuning Functions

Func.

Code

Name

R/W

Description

Network Data

Reg.

Range

Res.

Advertising