B–35 – Hitachi SJ200 Series User Manual
Page 249
Advertising
![background image](/manuals/88658/249/background.png)
SJ200 Inverter
Appendix B
B–35
Note 1:
Assume that the inverter current rating is 10000 (for B013/B213).
B130
Over-voltage
LADSTOP enable
R/W Pauses deceleration ramp when
DC bus voltage rises above
threshold level, in order to
avoid over-voltage trip.
Two option codes:
00... Disable
01... Enable
00A4h
0, 1
—
B140
Over-current trip
suppression
R/W Two option codes:
00... Disable
01... Enable
00A5h
0, 1
—
B150
Carrier mode (not
accessible to ModBus)
—
Automatically reduces the
carrier frequency as the
ambient temperature increases.
Two option codes:
00... Disable
01... Enable
00A6h
0, 1
—
“B” Group Fine Tuning Functions
Func.
Code
Name
R/W
Description
Network Data
Reg.
Range
Res.